UTI0,5-115 206926 Y7-206926 EATON ELECTRIC Transformador de mando 500 VA Monofásico Primario: 208-600 V Secundario: 2×115 V

UTI0,5-115 206926 Y7-206926 EATON ELECTRIC Transformador de mando 500 VA Monofásico Primario: 208-600 V Secundario: 2×115 V

En stock
Marca:
Disponibilidad:

Transformador de mando; 500 VA; Monofásico; Primario: 208-600 V; Secundario: 2×115 V

Transformador de mando. 500 VA. Monofásico. Primario: 208-600 V.

Eaton Moeller® series UTI Control transformer, 0.5 kVA, Rated input voltage 208 – 600 V, Rated output voltage 2 x 115 V

Transformador de control, Gama de productos: Transformadores multidevanado UTI monofásicos, Tensión de entrada nominal: 208 – 600 V, Tensión de salida nominal: 2 x 115 V, Potencia nominal: 0,5 kVA, Grado de protección: IP00, Normas Construido y probado para: transformadores de control, aislamiento y seguridad (universales) para, VDE 0550, IEC/EN 61558-2-2/2-4/2-6, VDE 0570 Parte 2-2/2-6 (transformador de seguridad), VDE 0570 Parte 2-4 (transformador de aislamiento), Adecuado para su uso a: IEC/EN 60204-1, ÖVE-EN 13, VDE 0113, VDE 0100 Parte 410

Código: 206926 Categorías: ,

Descripción

Especificaciones generales

Product Name
Eaton Moeller® series UTI Control transformer
Catalog Number
206926
EAN
4015082069261
Product Length/Depth
120 mm
Product Height
124 mm
Product Width
121 mm
Product Weight
6.8 kg
Certifications
CE
UL Recognized
CSA-C22.2 No. 66.1-06
UL 5085-2
UL5085-1
UL Category Control No.: XPTQ2, XPTQ8
IEC/EN 60204-1, ÖVE-EN 13
IEC/EN 61558-2-2
CSA-C22.2 No. 66
VDE 0570 Part 2-2/2-6 (safety transformer)
UL report applies to both US and Canada
Certified by UL for use in Canada
UL 506
IEC/EN 61558-2-2/2-4/2-6
VDE 0113, VDE 0100 Part 410
CSA-C22.2 No. 66.2-06
UL File No.: E167225
VDE 0570 Part 2-4 (isolating transformer)
VDE 0550
Catalog Notes
Electrical characteristics: all details for no-load loss, short-circuit loss (copper losses), short-circuit voltage and efficiency values relate to a temperature of 20 °C
Model Code
UTI0,5-115

Características y Funciones

Features
Separate windings
Fully Vacuum-impregnated
Reinforced insulation

General

Ambient operating temperature – min
-25 °C
Ambient operating temperature – max
40 °C
Connection type
Terminations
Duty factor
100 %
Insulation class
B
Primary tapping
± 20 %
Product category
Single-phase UTI multi-winding transformers
Suitable for
Branch circuits, (UL/CSA)

Especificaciones eléctricas

Efficiency
91.8 %
No-load losses
26 W
Rated frequency – min
50 Hz
Rated frequency – max
60 Hz
Rated power
0.5 VA
Relative short-circuit voltage
3.5 %
Short-circuit losses
23 W
Voltage rating – max
600 V

Verificación del diseño

Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
49 W
10.2.2 Corrosion resistance
Meets the product standard’s requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard’s requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard’s requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard’s requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard’s requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard’s requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard’s requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder’s responsibility.
10.8 Connections for external conductors
Is the panel builder’s responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder’s responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder’s responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder’s responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
ETIM for 206926 Interruptores de baja tensión (EC002486)
Característica Valor
Ejecutado como transformador de seguridad (EF007235)
Ejecutado como transformador de separación (EF007238)
Ejecutado como transformador de ahorro (EF007005) No
Tensión primaria 1 (EF006125) 208 V
Tensión primaria 2 (EF006126) 0 V
Tensión primaria 3 (EF006127) 0 V
Tensión primaria 4 (EF007410) 0 V
Tensión primaria 5 (EF007411) 0 V
Tensión primaria 6 (EF007412) 0 V
Tensión primaria 7 (EF007413) 0 V
Tensión primaria 8 (EF007414) 0 V
Tensión primaria 9 (EF007415) 0 V
Tensión primaria 10 (EF007409) 0 V
Tensión secundaria 1 (EF007472) 115 V
Tensión secundaria 2 (EF007474) 115 V
Tensión secundaria 3 (EF007475) 0 V
Tensión secundaria 4 (EF007476) 0 V
Tensión secundaria 5 (EF007477) 0 V
Tensión secundaria 6 (EF007478) 0 V
Tensión secundaria 7 (EF007479) 0 V
Tensión secundaria 8 (EF007480) 0 V
Tensión secundaria 9 (EF007481) 0 V
Tensión secundaria 10 (EF007473) 0 V
Potencia aparente nominal (EF008864) 500 VA
Consumo en modo de espera (EF012331) 21 W
Tipo de material de aislamiento según IEC 85 (EF007299) B
Protección contra cortocircuitos (EF007332) No
Tensión de cortocircuito relativa Uk (EF007452) 3.5 %
Anchura (EF000008) 121 mm
Altura (EF000040) 124 mm
Profundidad (EF000049) 120 mm
Grado de protección (IP) (EF005474) IP00
Núcleo anular (EF006170) No
Apto para montaje en PCB (EF006157) No
Apto para instalación en serie (EF001126) No
Material del conductor (EF001622) Cobre

Datasheet – PDF

Valoraciones

No hay valoraciones aún.